SystemSolution "Retention roof" Meander system 1-5°

Green roofing Brief description
Supply and install...
... mē Green roofing Optigreen protection and storage mat type RMS 300/500** as protection for the root-resistant roof membrane
... mē Green roofing Optigreen Meander panels as a drainage system with a discharge delay effect: Discharge coefficient C (per FLL) for 1° roof slope: 0.17; steady water storage capacity: 17 l/mē; temporary water storage capacity: 15 l/mē
... mē Green roofing Optigreen filter mat type 105 as filter layer between drainage layer and extensive substrate
... pcs. Green roofing Optigreen inspection chamber fitted over the roof outlets
... mē Green roofing 60 mm Optigreen extensive substrate type E
... mē Green roofing Optigreen hydro-seeding with Optigreen seeds type E and 50 g Sedum sprouts for fast and reliable vegetation establishment
... mē Green roofing maintenance care

      Weight details refer to saturated conditions; dry weight is ca. 60-70 %.